Sequence of Operation
System Sequence of Events
Objective Equipment List
¨ Apex Destiny 6100 control panel,
rev. 8.05 or greater
¨ Apex RK36 or RKLCD keypad
- Quick Exit Without Disarming -
With the system armed, provide the ability
to temporarily shunt a zone or zones by
simply pressing a single keypad function
key (F1 or F2), allowing quick exit without
having to disarm then re-arm.
Press a keypad function key (F1 or F2), then exit through the appropriate zone. Upon returning,
press the function key again.
Note: As a safeguard, the control panel will automatically remove the shunt
after ten minutes (programmable).
1) Pressing the keypad function key (F2 will be used for this Application Note) will send an
ON command to Control Channel 1.
2) Control Channel 1 is programmed to energize the on-board relay (Auxiliary Output 8) which will
drop a 4.7k resistor across the contact switch/zone loop to be shunted.
3) Pressing the keypad function key again (F2) will send an OFF command to Control Channel 1.
The on-board relay will de-energize and remove the 4.7k resistor from the contact switch/zone
loop.
4) The control panel will also send an OFF command to Control Channel 1 ten minutes after first
pressing F2.
Note: This Application is for hardwired contacts/devices only.
This application can be used in providing convenience when letting the
dog out or taking the trash to the street.
Apex Technical Support 800-272-7937
Option 1
Page 4-1
- Application Note -
End User Convenience