Sequence of Operation
System Sequence of Events
Objective Equipment List
For any alarm, provide a
delay period before the
external alarm speaker is
active.
¨ Apex Destiny 6100 control panel,
rev. 8.05 or greater
¨ External Speaker
(8 ohm - 10 watt minimum)
- External Alarm Delay -
1) Upon any alarm activation the system will send an ON command to Control Channel 1
energizing the on-board relay for a programmable time period. The common wire for the
external speaker will be interrupted disabling the speaker.
2) After the programmed time period the system will send an OFF command to Control
Channel 1 de-energizing the on-board relay. The common wire for the external speaker
will be restored enabling the speaker and allowing the alarm to be annunciated.
For any alarm activation the external speaker will be disabled for a programmed
time period before sounding an alarm. The internal speaker alarm will remain
instant.
This application allows the end user a period of time to disarm the
control after any activation before the alarm speaker disturbs neighbors.
Apex Technical Support 800-272-7937