Terminator
(CR-LF) Message terminator. ASCII characters consisting of hexadecimal 0x0D and
0x0A.
5.2. Arm and Disarm Messages
You can use the PC to arm and disarm the panel and to query the panel’s arming status.
For Arm and Disarm messages the data field
DDDDDD
consists of the two digit User Number
(01-32) followed by the 4 digit User Code (for RS-232 controlled panels always use 4 digit
arm/disarm codes.).
Arming the panel with zones open will initiate “force arming” regardless of whether force
arming is enabled or disabled in the panel.
You can use the PC to request the arming status of the system by sending an Arming Status
Request. The Panel will respond with an Arming Status Report.
Arm to Away
0Eaa
DDDDDD
00
CC
(CR-LF)
Example: User 2, User Code 2345, sending Arm to Away : 0Eaa0223450039(CR-LF).
Arm to Home
0Eah
DDDDDD
00
CC
(CR-LF)
Example: User 3, User Code 7898, sending Arm to Away : 0Eah037898001F(CR-LF).
Disarm
0Ead
DDDDDD
00
CC
(CR-LF)
Example: User 1, User Code 1000, sending Disarm : 0Ead0110000044(CR-LF)
Arming Status Request
08as0064(CR-LF)
The panel responds to this message with an Arming Status message
Arming Status Report
10AS
DDDDDDDD
00
CC
(CR-LF)
The panel sends this message in response to a Status Request
The 8-character data field represents the arming status of partitions 1-8. Each partition field
can contain one of the following values:
A Armed to Away
H Armed to Home
D Disarmed
6