Release 5.0
For use with Destiny 6100
Rev 8.05 or higher software.
DESTINY 6100 RS-232 Interface Specification
apex
K1231 9/98
RS232
Przeglądanie stron 0
1 2 3 4 5 6 ... 13 14

Podsumowanie treści

Strona 1 - Rev 8.05 or higher software

Release 5.0For use with Destiny 6100Rev 8.05 or higher software.DESTINY 6100 RS-232 Interface SpecificationapexK1231 9/98RS232

Strona 2

Table 5.6.1: System Notification Report Types (TT)Code Type Code Type Code Type00 Exterior Instant 11 Zone trouble 22 Zone unbypass01 Exterior Delay 1

Strona 3 - Contents

5.7. Bus CommandsYou can use your PC to send bus commands. These are currently restricted to keystrokesfrom a keypad to the panel, but the message is

Strona 4 - 2. General

programming information. USE THIS FEATURE WITH EXTREME CAUTION AND ATYOUR OWN RISK!The variable-length data field begins with 2 characters(0x00-0x20)

Strona 5 - 5. Messages

Appendix A: C Source for Command String Generator#include <stdio.h>#include <math.h>#include <stdlib.h>#include <string.h>void

Strona 7

This Page Intentionally Left Blank

Strona 8

Contents1. Conventions of this Document ... 42. General...

Strona 9

1. Conventions of this DocumentText displayed on your PC uses a monospaced font, and variable text is in an italicmonospaced font. Hexadecimal numbers

Strona 10

4. Error CheckingThis release is a “blind” protocol designed to be used when the data link is considered to be100% reliable. Future release versions

Strona 11

Terminator(CR-LF) Message terminator. ASCII characters consisting of hexadecimal 0x0D and0x0A.5.2. Arm and Disarm MessagesYou can use the PC to arm a

Strona 12

If partitioning is not used or not available, all 8 data fields will contain the same value. Fieldsfor partitions not assigned to a User will display

Strona 13

Zone Partition Report68ZPD...00CC(CR-LF)The panel sends this message in response to a Zone Partition Request.The data portion of this message is 96 ch

Strona 14

Control Channel off0AcfDD00CC(CR-LF)Example: turn on Control Channel 1: 0Acf0105(CR-LF)Control Channel Status Request08cs0062(CR-LF)The panel will res